Models: BSBP, BSDDP
©2014 Aerovent
Aerovent Catalog 172 provides additional information on this equipment. This catalog
can be found at www.aerovent.com or by contacting your local Aerovent sales representative.
Model Nomenclature
BSBP BSDDP
BSDDP - 24 - B - 1 - 05 - 25
Model
BSDDP = Wall Propeller Fan, Direct Drive
BSBP = Wall Propeller Fan, Belt Driven
Fan Size
Propeller Type
B = Backswept
Hub Designation
Blade Count
Blade Angle
General Installation, Operation and Maintenance Instructions For Aerovent Products
IM-172
August 2014
Propeller Wall Fans
Zobrazit stránku 0
1 2 3 4 5 6 ... 15 16

Shrnutí obsahu

Strany 1 - Propeller Wall Fans

Models: BSBP, BSDDP©2014 AeroventAerovent Catalog 172 provides additional information on this equipment. This catalog can be found at www.aerovent.com

Strany 2

10 Aerovent IM-172Fan bearings on belt driven fans should not need to be replaced for many years if the previous recommenda-tions are strictly

Strany 3 - Electrical Connection

Aerovent IM-172 11Figure 5. Eliminate Slack Figure 6. Belt DeflectionFigure 7. Alignment Figure 8. BeltsFigure 9. 2-Groove SheavesDeflectionDeflect

Strany 4 - Speed Control Installation

12 Aerovent IM-172Fan Troubleshooting Chart PROBLEM POSSIBLE CAUSES FAN DOES NOT OPERATE 1. Wrong voltage. 2. Electricity turned off or no

Strany 5

Aerovent IM-172 13Dimensional DataBSDDP – Direct Drive AIRFLOW AIRFLOWD MAXD MAXA DIA.C SQ. OUTSIDEA DIA.BB2.002.00BSDDPSIZEA B C SQ.D MAXDAMPER SI

Strany 6 - 6 Aerovent IM-172

14 Aerovent IM-172Dimensional DataBSBP – Belt Driven, Levels 1 & 2BSBP – Belt Driven, Level 3, Sizes 21-36 AIRFLOW AIRFLOWC SQ. OUTSIDEA DIA.D

Strany 7 - Flush with Interior Wall

Aerovent IM-172 15 AIRFLOW AIRFLOWBBC SQ. OUTSIDE D MAX D MAX2.002.00A DIA. A DIA.BSBPSIZEA B C SQ.D MAXDAMPER SIZEMAX MOTOR FRAMEEXHAUST SUPPLY42

Strany 8

AEROVENT | WWW.AEROVENT.COM5959 Trenton Lane N | Minneapolis, MN 55442 | Phone: 763-551-7500 | Fax: 763-551-7501 ®

Strany 9 - Maintenance

2 Aerovent IM-172StorageIf fans are stored for any length of time, they should be stored in a clean, dry location to prevent rust and corro

Strany 10 - Bearing Replacement

Aerovent IM-172 3Check, Test & Start ProcedureWARNINGElectric shock hazard. Could cause severe injury or death. Failure to bond the frame of this

Strany 11 - INCORRECT

4 Aerovent IM-172Figure 2. Low End Setpoint AdjustmentNOTE: 5 amp model shown. On 10 and 15 amp models, adjustment is made through clearance hol

Strany 12 - Fan Troubleshooting Chart

Aerovent IM-172 5FANAIR FLOWBACKDRAFTDAMPERSPACER(BY OTHERS)MINTo achieve the minimum 'M' dimension, this installation requires a spacer (b

Strany 13 - Dimensional Data

6 Aerovent IM-172OFFONRemovable ScreenPanel FanOSHA Motor Side GuardBackdraft DamperWeatherhoodDamper GuardBird ScreenWall CollarDisconnectSwitchOFFO

Strany 14

Aerovent IM-172 7Mounting Arrangements — With Wall Collar or Wall BoxFlush with Outside Wall WEATHERHOOD WITH SCREEN BACKDRAFT DAMPER MOUNTING FLANGE

Strany 15

8 Aerovent IM-172Wall Collar, Wall Box HousingsThe wall collar and wall box are intended to give the panel fan an easy way to adapt other accessories

Strany 16 - AEROVENT

Aerovent IM-172 9MaintenanceInstallation and maintenance are to be performed only by qualified personnel who are familiar with local codes and regula